CyberPower RB1280X2D príručka

(1)
  • +
    -
    -
    +
    -
    +
    -
    +
    1
    32
    MODEL: CP850AVRLCD, CP1000AVRLCD
    1
    2
    3
    1. Place the UPS on its top and remove the retaining screw (figure 1).
    2. Slide the battery compartment cover completely off of the unit (figure 2).
    3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement
    battery by connecting the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the
    battery. (figure 3)
    4. Slide the battery compartment cover over the battery and tighten the retaining screw.
    5. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.
    1. Place the UPS on its side and locate the battery compartment cover on the bottom of the UPS. Remove the four (4)
    retaining screws and pull the battery compartment cover off the UPS (figure 1 & 2).
    2. Remove the battery from the compartment and disconnect the battery wires from the batteries. Install the
    replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack. Put
    the battery pack into the compartment (figure 3).
    3. Slide the battery compartment cover over the battery and tighten the retaining screw. Charge the unit for 4 – 8 hours
    to ensure the UPS performs expected runtimes.
    1. Carefully turn the UPS on its side. Remove the 6 retaining screws and the cover.
    2. Disconnect the black and red cable from the battery set.
    3. Remove the battery protection cover and take the battery pack out of the compartment.
    4. Slide a new battery pack into the unit. Assemble the battery protection cover,cable, screws in the reverse order of
    the previous steps. Recharge the unit for 4-8 hours to ensure the UPS performs expected runtime.
    1. Carefully placed the UPS on its side. Remove the 2 retaining screws then push the battery cover backward and
    remove the cover.
    2. Disconnect the battery wires from the battery, and then remove the battery from the compartment.
    REMINDER: For PP800/PP1100/PP1500T, 2 batteries are attached with one single plastic strip. You can pull the
    plastic strip to pull out the battery.
    3. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting
    the black wire to the negative (-) terminal of the battery.
    4. Slide the battery back into the compartment. Carefully turn the UPS upside down to help the batteries slide all the
    way into the compartment. Replace the cover and the retaining screws. Recharge the unit for 4 – 8 hours to ensure
    the UPS performs expected runtime.
    1. Place the UPS on its side to locate and remove the front panel retaining screws from the bottom of the UPS.
    2. Slide the cover (front panel) towards the bottom of the UPS.
    3. Remove it from the unit.
    4. Disconnect the cable located at the top of the cover.
    5. Disconnect the battery wires from the batteries.
    6. Remove the batteries from the compartment.
    7. Install the replacement batteries by connecting the red and black wires to the same color wires from the battery
    pack. Put the battery pack back into the compartment.
    8. Replace the battery compartment cover and tighten the retaining screw. Charge the unit for 4-8 hours to ensure the
    UPS performs expected runtimes.
    Intelligent LCD Series
    1
    2
    3
    6
    4
    5
    AVR Series
    1
    3 4
    2
    Professional Tower Series
    MODEL: PP800SW
    MODEL: PP1500SWT4, PP2200SW
    1 2
    4
    3
    K09-0000065-00
    BATTERY REPLACEMENT
    K09-0000065-00
    BATTERY REPLACEMENT
    MODEL: CP600LCD, CP825LCD, CP800AVR, CP685AVR-G, CP825AVR-G, CP685AVRLCD-G,
    CP825AVRLCD-G
    MODEL: CP900AVR, CP1200AVR, CP1500AVRT, CP1285AVRLCD, CP1350AVRLCD,
    CP1500AVRLCD

Máte otázku týkajúcu sa CyberPower RB1280X2D?

Počet otázok: 0

Tu sa jednoducho opýtajte na otázku, ktorú máte ohľadom CyberPower RB1280X2D od ostatných vlastníkov produktov. Poskytnite jasný a komplexný popis problému a vašej otázky. Čím bude lepšie opísaný váš problém a otázka, tým ľahšie bude pre ostatných CyberPower RB1280X2D vlastníkov, poskytnúť vám správnu odpoveď.

Tu si zobrazte bezplatne CyberPower RB1280X2D príručku. Už ste si prečítaly príručku, ale nezodpovedala vám vašu otázku? Položte svoju otázku na tejto stránke ostatným CyberPower RB1280X2D vlastníkom. Tu položte otázku

Produktové špecifikácie

Všeobecné
Značka CyberPower
Model RB1280X2D
Výrobok Batéria
EAN 649532607853
Jazyk Engels
Typ súboru PDF
Vlastnosti
Typ batérie Sealed Lead Acid (VRLA)
Kapacita batérie 8 Ah
Napätie batérie 12 V
Kompatibilita CP1285AVRLCD, CP1200AVR
Farba Čierna
Počet batérií v cene 2 kusov
Hmotnosť a rozmery
Hmotnosť 5466 g
Šírka 202.1 mm
Výška 63.5 mm
Hĺbka 150.9 mm
Prevádzkové prostredie
Prevádzkový rozsah teplôt (T-T) 0 - 40 °C
Odporúčaná prevádzková vlhkosť 0 - 90 %
Údaje o balení
Šírka balenia 304.8 mm
Výška balenia 93 mm
Hĺbka balenia 250 mm
Hmotnosť vrátane balenia 6078 g

príručky.sk

Hľadáte príručku? príručky.sk zaistí, že nájdete príručku, ktorú hľadáte, ihneď. Naša databáza obsahuje viac ako 1 milión PDF príručiek od viac ako 10 000 značiek. Každý deň pridávame najnovšie príručky, aby ste vždy našli produkt, ktorý hľadáte. Je to veľmi jednoduché: stačí do vyhľadávacieho panela napísať názov značky a typ produktu a okamžite si môžete bezplatne a online prezrieť príručku podľa svojho výberu.

príručky.sk

© Autorské práva 2021 príručky.sk. Všetky práva vyhradené.